Need a Custom Solution?
23 products
Sort by:
23 products
Swab, snap, squeeze. It's that easy.
Using UltraSnap couldn't be easier. The three step process for collecting a sample, activating the device, and mixing the sample is so easy, anyone can do it.
Benefits
- Costs up to 50% less than other ATP swabs
- Results in 15 seconds
- Consistent, reliable results
- Pre-moistened swab bud
- Self-contained, liquid-stable reagent
- Write-on swab label for easy sample identification
- Environmentally conscious design - uses 20 - 80% less plastic than comparable devices
- Recyclable #7
- Patented Snap-Valve™ technology - snap & squeeze
- Unprecedented accuracy and reproducibility
- Tolerant to temperature abuse
- Test wet or dry surfaces
Specifications
- High sensitivity: Detects 0.1-1 femtomoles of ATP
- For detection to 0.1 femtomoles of ATP, use EnSURE™
- For dectection to 1 femtomoles of ATP, use SystemSURE Plus
- Shelf life:
- 15 months at refrigerated temperatures (2-8 ºC)
- 4 weeks room temperature (21-25 ºC)
- Compatible Luminometers
No interpretation required.
The results couldn't be easier to read with Pro-Clean. If protein is present in a sample, the reagent in the device will turn purple for immediate verification that is simple for any user to understand without interpretation or instrumentation. To learn more, watch the video above.
Reliable and accurate changeover cleaning verification.
Why test for protein residue? Protein is more difficult to remove from surfaces than glucose or other residues, so it's a good indicator for surface contamination. If you need to verify protein removal quickly, PRO-Clean is reliable and accurate.
Benefits
- Results in 1-10 minutes depending on sensitivity required - Instant results allow for immediate corrective action
- Easy-to-interpret color change
- All-in-one device- no instrumentation required
- Quick and easy way to monitor HACCP/SSOP program
- Cost effective
- No training required
- Recyclable #7
Specifications
- 80 µg after 1 minute
- 50 µg after 5 minutes
- 20 µg after 10 minutes
- Patented Snap-Valve™ technology - snap & squeeze
- Pre-moistened swab bud
- Write-on swab tube label
- Shelf life:
- 18 months at room or refrigerated temperatures (2 - 25°C)
Better design gives better results.
The honeycomb shaped dipper tip used with AquaSnap collects exactly 100µl of sample, making sure you are collecting the same amount every time. Other ATP water tests use a swab designed for surface sample collection which causes large sample variation. Surface swabs are pre-moistened with an extractant, so the absorption rate will vary based on how much sample can be absorbed. In addition, extractant will be lost when first dipped into sample. AquaSnap's honey dipper collection tip eliminates these issues providing more accurate results.
Liquid-stable chemistry.
AquaSnap contains liquid-stable chemistry in the patented Snap-Valve™ bulb. The unique chemistry and design eliminate the need to reconstitute lyophilized pellets, enabling consistent results. The chemistry in AquaSnap is a high power, ultra-sensitive formulation to deliver precise results for low levels of ATP. AquaSnap's chemistry is robust and resistant to harsh samples or sanitizer effects.
Benefits
- Ready-to-use out of box
- Easy-to-use and reduces user variation
- Patented design produces repeatable and accurate results
- Tolerant to temperature abuse and sanitizers
- All-in-one test device with collection dipper tip
- Consistent sample collection (100 µl) over swab or sponge tip test
- Liquid-stable chemistry eliminates the need to reconstitute a pellet, giving more accurate results with less variation
- True and accurate results at low RLU levels
- Reliable trending at low ATP and low RLU levels
- Low carbon footprint - Recyclable #7
Specifications
- Shelf life:
- 15 months at refrigerated temperatures (2-8ºC)
- 4 weeks room temperature (21-25ºC)
- Compatible Luminometers
Specifications
- Insulated construction
- Wide zipper top for easy access to swabs
- Large enough to hold several bags of Hygiena swabs
- Front zipper pocket perfect for luminometer or Calibration Control Kit storage
- Side mesh pocket ideal for notes or kit insert instructions
- Adjustable, padded shoulder strap
- 10.75″ W x 9.5″ H x 6″ D
Easy-to-interpret color results.
It doesn't take a microbiologist to understand these results. When Salmonella species is present in a sample, the liquid medium changes color from purple to vivid yellow.
No more unnecessary work.
Cut back on excessive labor and materials. This all-in-one test utilizes a large foam sampler for maximum sample collection that eliminates the need for additional sponges, diluents, bags, and pipettes. The only equipment you'll need is an Incubator.
Benefits
- Delivers results in 24 - 48 hours
- Cost-effective environmental monitoring solution
- Self-contained reagent- no transfers minimizing the chance of contamination
- Color-changing device is easy to interpret
- Only equipment required is a 37 ± 1 °C incubator - reduces materials and labor
Specifications
- Snap-Valve™ technology - snap & squeeze
- Large 2.5-inch foam swab for maximum sample pickup
- Write-on swab label for easy sample identification
- Presumptive positive results are available in as little as 24 hours
- Presumptive positive samples can be confirmed by streaking samples onto commonly used selective Salmonella agar plates or any recognized confirmatory procedure. Typical Salmonella colonies on selective agar plates could then be further analyzed by using biochemical, immunological, or molecular methods.
- Sensitive to 1-10 CFU
Test in-house, save valuable time.
InSite Listeria complements your lab testing with quick on-site screening results in just 24-48 hours. Eliminate the lengthy wait time for outside lab results and get ahead of contamination issues.
Easy-to-interpret color results.
It doesn't take a microbiologist to understand these results. When Listeria species is present in a sample, the liquid media changes color from amber to black.
Benefits
- Delivers results in 24-48 hours
- Cost-effective test
- Self-contained reagent- no transfers minimizing the chance of contamination
- Color-changing device is easy to interpret
- Only equipment required is a 37°C ± 1° incubator - reduces materials and labor
Specifications
- Snap-Valve™ technology - snap & squeeze
- Large 2.5-inch foam swab for maximum sample pickup
- Write-on swab label for easy sample identification
- Presumptive positive results are available for the most common Listeria spp in as little as 30 hours at levels as low as 1-10 CFU/mL
-
- Presumptive positive samples should be confirmed by streaking sample onto commonly used selective Listeria agar plates such as Modified Oxford agar, Palcam agar, or any other recognized confirmatory procedure. Typical Listeria colonies on selective agar plates could then be further analyzed by more definitive tests such as microscopy, biochemical tests, etc.
- Compared to UVM and BLEB, provides superior/equivalent recovery and faster detection of as low as 10-50 heat injured Listeria monocytogenes/mL within ~24-30 hours of incubation.
- Provides higher level of selectivity and sensitivity for heat injured L. monocytogenes under binary competition conditions compared to BLEB and UVM media
- 12-month shelf life at refrigerated temperatures (2 - 8 °C)
The proof is in the color.
Green means clean, and purple means re-clean. Protecting your product quality and ensuring customer safety has never been easier. The more protein in your sample, the deeper and dark the purple becomes. There's even a color chart printed on the label to help with interpretation and eliminate any guesswork.
Benefits
- Results in 15-30 minutes depending on sensitivity requirements
- Proactive, qualitative approach to verification
- Broad range, non-specific protein screening is more cost-effective when specific tests are not required
- Eliminates mistakes and waste
- No separate wetting agent required
- No reconstitution step ensure consistent repeatable results
Specifications
- All-in-one device
- Pre-moistened swab provides reliable collection recovery and detection to ensure consistent reliable results
- Easy to use and activate
- Patented Snap-Valve™ technology - snap & squeeze
- Write-on swab tube label
- Temperature stable, sensitive liquid-stable chemistry
- Small, light-weight device
- Low carbon footprint (100% recyclable) - Recylable #7
- Shelf life:
- 18 months at room or refrigerated temperatures (2 - 25°C)
- Sensitivity:
- Detects 3 µg protein after 15 minutes at 55°C or 30 minutes at 37°C
